undefined
undefined
undefined
undefined
+
  • undefined
  • undefined
  • undefined
  • undefined

Model: 3KM-JYMT330-100277-C1-5092

Sunlight Simulation System


1. This system features white, silver, champagne gold, bronze and more color and customization. Its wide application range covers: study, work stations, concealed underground, living rooms, restaurants, recreation rooms, nurseries, rehabilitations, light therapy, and application demands sunlight. The full-spectrum light helps calcium absorption, blood circulation, and wound healing. It also enhances immune function, provides antibacterial and anti-inflammatory effects, and helps prevent infectious skin diseases; improves mood, regulates the biological clock, alleviates depression, and enhances sleep quality.

2. Red, green, and blue light that produce by the system are consistent with natural sunlight. Objects illuminated by it appear clear, natural, and comfortable, as if under sunlight. It is flicker-free and free from harmful blue light, effectively reducing visual fatigue and promoting long-term eye health, therefore particularly suitable for applications that require high color rendering and eye protection, such as calligraphy, painting, carving, reading, photography, color matching, and inspection.

Categroy:

Sunlight Simulation System

Keyword:

Sunlight Simulation System

Introduction


Vitamins Can’t Bring Sunlight

On sunless days, no amount of vitamins can give you sunlight, health, or a warm, happy life.
But this light turns electricity into sunshine. Every day. For you and your family.

Sunbath at Work

Long-term windowless work forces a cycle of duty then recovery — harming both health and time.
Our sunlight system delivers real UV and IR, regulating your body clock just like natural sun.
Even in a deep-sea lab, you can work and enjoy a sunbath at the same time.

Sunlight on Demand

RGB ratio matches sunlight — so objects look as clear, natural, and comfortable as under the real sun.
No flicker. No blue light risk. Reduces eye fatigue.
Protects your eyes through long hours of detailed work, helping your craft shine with precision and quality.

Feel the Brilliance of Natural Light

Sunlight offers real benefits — especially for newborns, the elderly, and the injured.
It helps infants absorb calcium, boost immunity, metabolize, and fight jaundice.
It improves circulation, heals wounds, kills germs, and prevents skin infections for the injured or ill.
But time, weather, location, and safety often make real sun exposure unreliable.
Until now.

Late-Night Sunbath with Friends

Play cards. Do business. Bond with friends.
All while soaking in sunlight — at night.

Sunlight Scene Simulation

Customizable beam angle and CCT.
Simulate a wide range of sunlight scenes —
golden light in a temple, warm glow in a chapel, natural daylight in modern architecture.

Technical Specifications


Item Unit Parameter
Input Voltage V AC100-277
Power Frequency Hz 50/60
Rated Power W 330
Power Factor / >0.90
Output Angle ° 75
Color Temperature K 5000
Color Tolerance / 3.3
Luminous flux Lm >15000
CRI / 92
Light Source / light emitting plasma (LEP)
IP Rating / IP44
Life Span hrs >50000
Dimension mm Φ498*H252
Weight Kg 12

Spectral Curve

Application


Installation Height vs. Illumination Area

Installation Height (m) Beam Angle Floor Illumination Area (m²) Floor Average Illuminance (Lux) Floor Max Illuminance (Lux) Desk Average Illuminance (Lux) Recommended Ceiling Height (m)
2.0 75° 12 700 1200 750 ≥2.5
2.5 13 650 1180 680 ≥2.9
3.0 15 634 1149 645 ≥3.4
3.5 16 580 980 600 ≥3.8
4.0 18 359 648 420 ≥4.4
4.5 20 310 580 350 ≥4.8
5.0 25 258 414 280 ≥5.4

Note:
1. According to the latest mandatory national standard, the average illuminance on classroom desk surfaces is required to be ≥300 Lux.

2. Desk Height: 0.75m.

3. Installation Height: Distance from Fixture Bottom to Floor.

Installation

1. First, check and ensure that the power supply network is properly grounded。
2. Arrange for a qualified electrician or trained, certified personnel to operate the system.
3. Before installation, maintenance, or servicing, carefully read the specifications, labels, and markings.
4. Strictly use the product according to the working voltage and polarity indicated on the label.
5. During installation, properly insulate all wiring connections to prevent electric leakage.
6. The product has an IP44 protection rating and is suitable for indoor or semi-outdoor installation.
7. Do not cover the main body of the system with heat-insulating or flammable materials.
8. According to internal safety protocols, the light-emitting surface should face vertically downward during operation, with a maximum allowed tilt of 10 degrees.
9. During installation, ensure that the stainless steel safety cable is attached to the designated points on the main body and mounting plate.
10. After installation, make sure all screws fastening the ceiling mounting plate or flange are securely tightened.

11. Refer to manual for details.

Request Quote

If you want to inquire about our products, please fill out the form below, and we will contact you as soon as possible!

%{tishi_zhanwei}%

Related Products